Search found 42189 matches

by chulett
Tue Dec 15, 2009 4:33 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Lookup Stage Erroe
Replies: 10
Views: 6706

If your job is cratering early in the process then perhaps it hasn't gotten that far yet. From what I recall, the score is dumped just after the config file contents are logged and say "main_program: This step has".
by chulett
Tue Dec 15, 2009 4:28 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Error compiling Job Control Subroutine <JobName>
Replies: 7
Views: 10316

And you're certain this job is compilable in the original project? Perhaps you are missing user-defined environment variables, they are not included in a Project export.
by chulett
Tue Dec 15, 2009 3:33 pm
Forum: Information Analyzer (formerly ProfileStage)
Topic: Deploying a webservice for a sequence of jobs
Replies: 5
Views: 2634

My assumption was that "sequence of jobs" meant a "Job Sequencer" or "Sequence job". If you meant something else, please let us know.
by chulett
Tue Dec 15, 2009 2:58 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: are there Oracle plugins for versions 10g and 11g?
Replies: 3
Views: 1187

Your documentation should verify, but the current stages officially support up through 10g and pretty sure people here have reported using them with 11g.
by chulett
Tue Dec 15, 2009 2:02 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Job Scheduled did not ran
Replies: 6
Views: 2092

Mine was with UNIX server, so cron scheduled via Director.
by chulett
Tue Dec 15, 2009 12:24 pm
Forum: General
Topic: XML Input from a URL rather than a File Path
Replies: 7
Views: 1768

XML Input from a URL rather than a File Path

Has anyone had any success with using the XML Input stage with the Column Content option set to URL/File path and actually sending it a URL? I've always used it as a "file path" to a source local to the DataStage server and now I'm tasked with sourcing from files that have been "poste...
by chulett
Tue Dec 15, 2009 12:13 pm
Forum: Information Analyzer (formerly ProfileStage)
Topic: Deploying a webservice for a sequence of jobs
Replies: 5
Views: 2634

As far as I know, that answer would be... no.
by chulett
Tue Dec 15, 2009 12:10 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Retrieving multiple values from a sequence
Replies: 9
Views: 1913

No, by 'directly' I meant directly in the Surrogate Key Generator stage. Now granted, I've never done this myself as of yet, so just going by what I've read posted here but my understanding is that the stage can directly access the sequence and thus the fact that others may be using it at the same t...
by chulett
Tue Dec 15, 2009 11:18 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Retrieving multiple values from a sequence
Replies: 9
Views: 1913

Using the sequence directly would mean all that is already handled by the database.
by chulett
Tue Dec 15, 2009 11:03 am
Forum: General
Topic: Is there a debugger for DataStage version 8?
Replies: 6
Views: 4275

sumanth.punyamurthula@etr wrote:But we use Datastage Enterprise Edition also called Parallel Extender (PX).
You marked your Job Type as Server in your post, hence my answer.
by chulett
Tue Dec 15, 2009 11:00 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Oracle Enterprise stage insert problem
Replies: 8
Views: 1789

I didn't ask you to show me what it does look like but rather what it should look like, as in with the values properly substituted. Sounds like you want to select that date as a literal, yes?
by chulett
Tue Dec 15, 2009 9:24 am
Forum: General
Topic: Is there a debugger for DataStage version 8?
Replies: 6
Views: 4275

Yes, for Server jobs. The debugging menu is available from the Designer.
by chulett
Tue Dec 15, 2009 9:00 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: installation
Replies: 7
Views: 2716

Suddenly we're a warez site? WTF. :roll:

On the off chance you are a legitimate user and just confused as to where to go for that information, check with the company you work for, the one that legitimately provided you with their licensed software - they'll have the appropriate credentials.
by chulett
Tue Dec 15, 2009 8:53 am
Forum: General
Topic: Write Mode failure
Replies: 3
Views: 3217

"Unusable" indexes are a common result of a failed bulk load (typically dups in a unique index) and need to be resolved before running another.
by chulett
Tue Dec 15, 2009 8:51 am
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Job Scheduled did not ran
Replies: 6
Views: 2092

I've seen that myself years ago but Ascential support could never pin down a cause and it "went away" on its own. Perhaps by now they might have a clue. :wink: