guess its fine as is and no real interest to our audiance.
closing it
Search found 2288 matches
- Mon Feb 10, 2014 7:35 am
- Forum: Site/Forum
- Topic: Where Would you like to see special topics
- Replies: 3
- Views: 8449
- Mon Feb 10, 2014 7:33 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Migration to 9.1 and CRC32 function
- Replies: 9
- Views: 6150
- Mon Feb 10, 2014 6:12 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: wierd Iconv expresion
- Replies: 1
- Views: 2291
wierd Iconv expresion
Hi All,
seen this expresion in a job:
it does return the same as:
I was wondering was there something I missedd regarding Iconv
or is it simply a missused syntax (that accidentaly works) ?
Thanks,
seen this expresion in a job:
Code: Select all
iconv(myDate,"DYMD" : @VM : "MCN")
Code: Select all
Iconv(myDate,"DYMD")
or is it simply a missused syntax (that accidentaly works) ?
Thanks,
- Mon Feb 10, 2014 6:08 am
- Forum: General
- Topic: Using ODBC connection via DS Basic
- Replies: 6
- Views: 2669
- Tue Jan 28, 2014 6:19 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Unable to open file status=13
- Replies: 4
- Views: 3592
Unable to open file status=13
Hi All, I'm experiencing a weird behavior: If I have a job that writes to a sequential file and upon completion reads from that same file in the same job it fails saying: unable to open file <fname> status=13 all in 1 job: DB > Xfm > SF > Xfm > DB This fails 2 separate jobs: job1: DB > Xfm > SF job2...
- Tue Jan 21, 2014 9:58 am
- Forum: Site/Forum
- Topic: Where Would you like to see special topics
- Replies: 3
- Views: 8449
- Tue Jan 21, 2014 6:58 am
- Forum: Site/Forum
- Topic: Where Would you like to see special topics
- Replies: 3
- Views: 8449
Where Would you like to see special topics
Hi, Would you like to see special topics covered as Faq forum posts or as Sticky post in the relevant Foum? The idea is to gather Special Topics (ie: Backup, Clear logs,...) and to put the under the FAQ forum or as sticky posts in the forum the belong to. Any ideas regarding this, may be posted in r...
- Mon Jan 13, 2014 10:50 am
- Forum: General
- Topic: Export: Export job executables without design
- Replies: 1
- Views: 1642
IMHO, (In My Humble Opinion) The only reason to export without design is to hide your implementation. This means the project that imports the jobs will have no design, hence no way to maintain the jobs. Furthere more what will you do, if the job fails? you have no design to debug or fix in case it f...
- Mon Jan 13, 2014 10:42 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: remove string Dynamically
- Replies: 3
- Views: 2602
Hi, As craig said your example seems to have a changing algorithym 0000000002 000000000 ~0000000009~1001~ ~VENDOR~0000000138~1001~ ~VENDOR~0020009816~2001~ ~0020009816~2100~ in the above example you supplied there are several different logics for extracting the data rows 1+2 first and only field row...
- Sun Jan 12, 2014 10:37 am
- Forum: Site/Forum
- Topic: Mark As Unread
- Replies: 4
- Views: 8711
- Sun Jan 12, 2014 10:11 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Multiple Inputs to one CSV
- Replies: 4
- Views: 3495
Hi, If I understood correctly, you have severl source files that need to eventually be written to a single sequential files with the CSV format. So there are several solutions available, depending on the similarity or lack of, between your source files. Writing to a sequential files simultaniously f...
- Sun Jan 12, 2014 9:35 am
- Forum: General
- Topic: Drop wasadmin - Problems with WAS & Datastage authentica
- Replies: 3
- Views: 2405
- Wed Jan 08, 2014 6:08 am
- Forum: General
- Topic: Using ODBC connection via DS Basic
- Replies: 6
- Views: 2669
- Tue Jan 07, 2014 8:12 am
- Forum: General
- Topic: Using ODBC connection via DS Basic
- Replies: 6
- Views: 2669
Using ODBC connection via DS Basic
Hi all, in previous versions there was an ODBC header file in the dsinclude folder under each project. I now notice on a 8.5 installation that this file is no longer there. does that mean that we can no longer use a Basic routine/job control to use the DS Basic language to connect and utilize the od...
- Tue Jan 07, 2014 8:08 am
- Forum: General
- Topic: To get the status of Jobs
- Replies: 9
- Views: 6991