Search found 303 matches

by JPalatianos
Mon Feb 24, 2020 10:53 am
Forum: General
Topic: Unable to get to the Premium Membership sign up page
Replies: 3
Views: 12452

Unable to get to the Premium Membership sign up page

Hi,
I have tried to renew my Premium membership over a month ago and the page presents a 404 page not found error. I sent an email to the site admins and never heard back. I tried again today and received the same error.

Anyone else facing the same issue?

Thanks - - John
by JPalatianos
Fri Jun 30, 2017 12:35 pm
Forum: General
Topic: How to uninstall a Patch on 11.5 Linux Server
Replies: 1
Views: 3102

Finally found what I was looking for @
http://www-01.ibm.com/support/docview.w ... ingpatches
by JPalatianos
Fri Jun 30, 2017 8:45 am
Forum: General
Topic: How to uninstall a Patch on 11.5 Linux Server
Replies: 1
Views: 3102

How to uninstall a Patch on 11.5 Linux Server

Thought this would be a simple search on the IBM site but I could not find anything for it. I am looking to uninstall a patch I just installed on my new 11.5 Linux installation. The patch readme.txt states the uninstall is supported: PATCH FOR APAR : ISF rollup patch. See Problem section for list of...
by JPalatianos
Thu May 18, 2017 6:31 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Backslash in Admin variable dropped going into the query
Replies: 4
Views: 4193

Hi Julio, Thank You!! I could have sworn that I tried that up front but it appears I was never saving my changes when updating the administrative value. The [NJROS1BD0130\\DEV] ended up working for us. FYI.... The reason this application has the server name in some of their jobs is they sometimes de...
by JPalatianos
Wed May 17, 2017 5:50 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Backslash in Admin variable dropped going into the query
Replies: 4
Views: 4193

Hi Julio,
I tried the following in administrator:
[NJROS1BD0130/\DEV]
Now it gives me Could not find server 'NJROS1BD0130/DEV' in sys.servers.

A bit closer but we want it interpreted as 'NJROS1BD0130\DEV

Thanks - - John
by JPalatianos
Wed May 17, 2017 4:41 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Backslash in Admin variable dropped going into the query
Replies: 4
Views: 4193

Backslash in Admin variable dropped going into the query

Hi, We are migrating our 9.1 DataStage project from Windows to 11.5 running on Red Hat Linux. We have one project that uses the server name in the queries as follows: from #$Server#.#$PlanMartDB#.dbo.dly_finance_invst_info_dim The server variable is defined in administrator as [NJROS1BD0130\DEV]. Th...
by JPalatianos
Fri Feb 03, 2017 3:04 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Trying to pass a Cntrl A as a delimiter to Hadoop
Replies: 1
Views: 2745

Trying to pass a Cntrl A as a delimiter to Hadoop

Hi We are running DataStage 11.5 on Red Hat Linux and we are connecting to Cloudera's version of Hadoop utilizing the File Connector stage. The Hadoop admins are requesting that we use a ctrl-A as a column delimiter. They told us that the physical value is "\001". We tried putting this in ...
by JPalatianos
Thu Feb 02, 2017 7:24 am
Forum: General
Topic: Sequence and User Variable Activity stage during restart
Replies: 8
Views: 6136

Thank You for all the responses...I will ask IBM if there is any way to override this behavior and post back to the chat when I hear back.
by JPalatianos
Wed Feb 01, 2017 5:18 pm
Forum: General
Topic: Sequence and User Variable Activity stage during restart
Replies: 8
Views: 6136

Hi Craig, We had the sequence initially kick of at 9:39 PM and one of the jobs aborted. We then restarted the sequence at 11:39 PM and one of the variables in the User Variable stage uses the macro DSJobStartTimestamp for an assignment. We found that one of the later jobs that ran the second time ar...
by JPalatianos
Wed Feb 01, 2017 2:35 pm
Forum: General
Topic: Sequence and User Variable Activity stage during restart
Replies: 8
Views: 6136

Sequence and User Variable Activity stage during restart

Hi, I was curious what the behavior is when a sequence restarts. Specifically on the User Variable Activity that is before the job failure. For example...we have 2 jobs followed by the user variable activity followed by 7 jobs. If the job 6 after the UVA aborts and we reastart we assumed that the UV...
by JPalatianos
Tue Dec 06, 2016 9:39 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: DS connectivity with Hadoop
Replies: 8
Views: 8013

Hi,
I was just curious if you were ever able to configure your connectivity to Cloudera using the "Big Data File Stage"?

We have just been tasked with a similar exercise connecting to Cloudera from our 11.5 DataStage installation.

Thanks - - John
by JPalatianos
Fri Nov 04, 2016 3:20 pm
Forum: General
Topic: Entry in the odbc.ini file utilizing db2 client driver
Replies: 2
Views: 3159

Thanks Andy. I have been looking around and cannot seem to find an entry using the db2 client driver. We are looking for something like the ODBC.ini entry shown below for the DataDirect Wire protocol but specific for the DB2 Client Driver: DB2CLIO. [DB2 Wire Protocol]Driver=/opt/IBM/InformationServe...
by JPalatianos
Sat Oct 22, 2016 9:12 am
Forum: General
Topic: Entry in the odbc.ini file utilizing db2 client driver
Replies: 2
Views: 3159

Entry in the odbc.ini file utilizing db2 client driver

Hi, We are in the initial phases of migrating from Version 9.1 on Windows to 11.5 on LINUX and are looking to create an entry in our ODBC.ini file utilizing the DB2 client driver. The samples have entries utilizing the DB2 Wire protocol driver but we are looking for one for the DB2CLI.dll (that is w...
by JPalatianos
Tue May 03, 2016 5:58 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Parameter Set Value File Question
Replies: 4
Views: 4769

Parameter Set Value File Question

Hi, I tried searching for this but was not able to find anything on it. Is it possible to assign an administrative (Environment) Variable directly to a value file parameter (Values Tab) and not the default for that parameter in the Parameters tab. The application area is looking to have the ability ...
by JPalatianos
Fri Feb 05, 2016 6:00 pm
Forum: General
Topic: dsjob -ljobs with invocation id
Replies: 3
Views: 3160

Thank You but we do not have the operations console installed here.